Reach beyond the network.

A private LoRa link and a local alarm panel can monitor difficult locations without a site Wi-Fi router or internet connection on the local alarm path. Final performance requires site engineering and testing.

Catalogue humidity sensing; private LoRa compatibility and system scope require separate engineering.
Catalogue humidity sensing; private LoRa compatibility and system scope require separate engineering.

Select the sensing. Engineer the wireless path.

These catalogue instruments provide sensing and acquisition reference options. The private LoRa monitoring concept is engineered separately: the listed signal outputs do not imply LoRa compatibility.

Pressure & temperature

TEJ / CATALOGUETemperature instruments from the TEJ product catalogue

Temperature

04 / 08

Choose connection-head, cable, hygienic or thermocouple assemblies for machinery and process lines. Match the element, immersion length and sheath to the service. Thermowells and transmitters are selected separately to suit installation and control requirements.

RTD range guide
−196 to +600 °C
TC range guide
K/N: −40 to +1200 °C
View specifications
RTD range guide
−196 to +600 °C across suitable assemblies.
TC range guide
K/N: −40 to +1200 °C; class 2 examples.
Elements
Pt100 / Pt1000; thermocouple type to suit duty.
Signal chain
2/3/4-wire RTD; TC mV; transmitter: 4–20 mA.
Construction
Stainless sheath, selected length and connection.

Indicative industry selection data, not guaranteed ASTREON model ratings. Confirm the final range, accuracy and configuration against the selected manufacturer datasheet.

Discuss your requirement

Humidity, gas & dew point

TEJ / CATALOGUEHumidity instruments from the TEJ product catalogue

Humidity

04 / 08

Monitor air humidity and temperature using wall, duct or remote-probe arrangements. Select the filter and mounting for contamination, airflow and maintenance access. Accuracy must be assessed across the actual humidity and temperature conditions.

Relative humidity
0–100% RH
Outputs
Voltage / RS-485
View specifications
Relative humidity
0–100% RH.
Temperature guide
−40 to +80 °C, probe-dependent.
Accuracy example
±1.5% RH at 0–90% RH and 0 to +40 °C.
Outputs
Voltage or RS-485, selected by model.
Construction
Room / duct / remote probe; suitable filter.

Indicative industry selection data, not guaranteed ASTREON model ratings. Confirm the final range, accuracy and configuration against the selected manufacturer datasheet.

Discuss your requirement

Catalogue ranges, accuracy, approvals and operating conditions depend on the selected model and application. Detailed specifications are confirmed with your requirement.

A local alarm path, designed for your site.

Define the operating conditions, interfaces and acceptance criteria before selecting equipment or committing to system performance.

Sense

Select the sensor and its location against the temperature threshold and environment.

Transmit

Use a private LoRa link; validate range, obstructions, power and local radio requirements at the site.

Distinguish

The local display, buzzer and dry contacts distinguish low temperature, sensor fault and link loss.

Validate

Test communication failure, sensor faults, alarm recovery and the operator response before use.

System concept under validation. Coverage, battery life, temperature range and alarm performance are confirmed only after application review and site testing.

← Explore all Sensors & Instrumentation solutions

Define your wireless monitoring requirement.

Tell us about your process, site conditions and required outcome. We’ll help you define the next step.

Discuss your requirement ↗