Product information and resources.

The latest ASTREON sensor catalogue brings product images, application descriptions and indicative selection data together. Browse ten instrument families or download the complete eight-page guide.

ASTREON Sensors & Instrumentation — Industrial Sensing & Automation. Eight pages covering ten instrument families.
ASTREON Sensors & Instrumentation — Industrial Sensing & Automation. Eight pages covering ten instrument families.

Go directly to the instrument.

Each image is mapped to its corresponding family, application description and technical guide from the new catalogue.

Pressure instruments from the ASTREON sensor catalogue
CATALOGUE / PAGE 3

Pressure

Select compact transmitters, process instruments or local gauges for pumps, compressors and hydraulic systems. Match the measuring span, overload capacity, wetted materials and connection to the medium. Confirm the total error at operating temperature.

View selection data ↗
Differential pressure instruments from the ASTREON sensor catalogue
CATALOGUE / PAGE 3

Differential pressure

Compare pressure across filters, cleanrooms or process equipment. Air-DP transmitters use low measuring spans; process-DP instruments require suitable wetted materials and static-pressure ratings. Select the port arrangement, span and output for the installation.

View selection data ↗
Temperature instruments from the ASTREON sensor catalogue
CATALOGUE / PAGE 4

Temperature

Choose connection-head, cable, hygienic or thermocouple assemblies for machinery and process lines. Match the element, immersion length and sheath to the service. Thermowells and transmitters are selected separately to suit installation and control requirements.

View selection data ↗
Humidity instruments from the ASTREON sensor catalogue
CATALOGUE / PAGE 4

Humidity

Monitor air humidity and temperature using wall, duct or remote-probe arrangements. Select the filter and mounting for contamination, airflow and maintenance access. Accuracy must be assessed across the actual humidity and temperature conditions.

View selection data ↗
Flow instruments from the ASTREON sensor catalogue
CATALOGUE / PAGE 5

Flow

Select electromagnetic, thermal, turbine or ultrasonic measurement for the fluid. Define the working flow, pipe size and installation conditions. The conductivity limit and numerical examples below apply specifically to electromagnetic liquid measurement.

View selection data ↗
Level instruments from the ASTREON sensor catalogue
CATALOGUE / PAGE 5

Level

Select continuous measurement or point detection for tanks, vessels and silos. Radar, hydrostatic, float and vibrating-fork instruments address different duties. Review vessel geometry, deposits, foam, vapour and mounting before selecting the process connection and materials.

View selection data ↗
Load & weighing instruments from the ASTREON sensor catalogue
CATALOGUE / PAGE 6

Load & weighing

Choose bending-beam, single-point, S-type or compression cells for the structure and load path. Size each cell for dead load, working load and overload. Compatible mounting hardware and separate electronics complete the weighing system.

View selection data ↗
Gas detection instruments from the ASTREON sensor catalogue
CATALOGUE / PAGE 6

Gas detection

Specify the target gas first. Electrochemical, infrared and catalytic technologies serve different gases. Confirm units, cross-sensitivity, calibration and alarms. Any hazardous-area approval must match the exact instrument configuration and installation.

View selection data ↗
Dew point instruments from the ASTREON sensor catalogue
CATALOGUE / PAGE 7

Dew point

Monitor moisture in compressed air, dryers and suitable dry gases using compact probes, remote displays or sampling arrangements. Define pressure or atmospheric dew point explicitly. Match the sensor, pressure rating and sampling conditions to the required dryness.

View selection data ↗
Calibrators instruments from the ASTREON sensor catalogue
CATALOGUE / PAGE 7

Calibrators

Our calibrator offering supports commissioning and maintenance. Multifunction units source electrical and temperature-sensor signals; dry blocks and pressure pumps provide physical references. The benchmarks below apply to separate equipment types, with final model selection required.

View selection data ↗

What to send us.

Use this checklist for instrument selection or a system enquiry.

  1. Parameter and operating range; required accuracy or tolerance.
  2. Media, pressure, temperature and environmental conditions.
  3. Process connection, mounting, materials and installation constraints.
  4. Signal output, power supply, controller and communication protocol.
  5. Quantity, location, required documentation or approvals and delivery needs.
  6. For systems: alarm thresholds, response owner, integrations and records.
Email your requirement ↗

Current scope

Application review, instrument selection, sourcing and integration support.

Catalogue imagery

Grouped images show representative product concepts, not confirmed stock. Display readings are illustrative.

Technical selection data

Tables are indicative industry guides, not guaranteed ASTREON model ratings. Confirm the selected manufacturer datasheet, configuration and approvals.

System concepts

ServerGuard, private wireless monitoring and automated calibration require engineering and site validation.

Discuss your measurement requirements.

Tell us about your process, site conditions and required outcome. We’ll help you define the next step.

Discuss your requirement ↗