ASTREON Sensbox demonstration showing its surface-temperature, humidity, air-temperature, airspeed and differential-pressure connections

ASTREON Sensbox

Eight channels. One portable measurement system.

Bring surface temperature, humidity, air temperature, duct air velocity and filter differential pressure into one portable acquisition and recording case. Sensbox is designed around field connection, a visible logger and a matched backup-power path.

Sensor, channel and power mapping.

The channel assignments below follow the video. Live-looking screen values are illustrative, rather than calibration or test results.

Eight measurement channels, with humidity and air temperature sharing one remote probe. Channel numbering follows the supplied demonstration.

Sensor-to-channel mapping
ChannelMeasurementSensor / signal path
CH 01Supply duct surface temperatureSurface-contact thermocoupleThermocouple mV → type-matched conversion + cold-junction compensation → °C
CH 02Return duct surface temperatureSurface-contact thermocoupleThermocouple mV → type-matched conversion + cold-junction compensation → °C
CH 03Chilled-water supply surface temperatureSurface-contact thermocoupleThermocouple mV → type-matched conversion + cold-junction compensation → °C
CH 04Chilled-water return surface temperatureSurface-contact thermocoupleThermocouple mV → type-matched conversion + cold-junction compensation → °C
CH 05Relative humidityShared remote humidity / air-temperature probeInternal transmitter → independent 4–20 mA humidity signal → %RH
CH 06Air temperatureSame remote probe as channel 05Internal transmitter → independent 4–20 mA temperature signal → °C
CH 07Duct air velocityCable-connected thermal airspeed probeInternal transmitter → 4–20 mA → m/s
CH 08Filter differential pressureDifferential-pressure transmitter with HIGH / LOW tubesHIGH upstream − LOW downstream → internal transmitter → 4–20 mA → Pa

Battery & backup power

Battery shown
Bioenno Power BLF-2410A
Proposed battery configuration
24 V, 10 Ah LiFePO₄ compact protected pack
Power path
Matched charger and DC UPS path
Configuration check
Final load and enclosure to be verified, as stated in the demonstration

The video identifies this battery as a proposed configuration. Final battery, charger, DC UPS compatibility and load must be confirmed for the selected build; a verified operating runtime is not specified.

← Sensors & instrumentation catalogue

Build your Sensbox measurement plan.

Tell us about your process, site conditions and required outcome. We’ll help you define the next step.