Complete the measurement chain.

Bring field readings into an operator workflow with conditioning, acquisition, controllers, alarms and traceable history.

Humidity sensing with model-dependent voltage or RS-485 outputs.
Humidity sensing with model-dependent voltage or RS-485 outputs.

From field readings to connected records.

Review signal options on catalogue instruments, including 4–20 mA, voltage, HART and RS-485 where specified. Gateways, acquisition and control-system integration are selected separately around your architecture.

Pressure & temperature

TEJ / CATALOGUEPressure instruments from the TEJ product catalogue

Pressure

03 / 08

Select compact transmitters, process instruments or local gauges for pumps, compressors and hydraulic systems. Match the measuring span, overload capacity, wetted materials and connection to the medium. Confirm the total error at operating temperature.

Range options
0–0.4 to 0–1600 bar
Outputs
4–20 mA / 0–10 V
View specifications
Range options
0–0.4 to 0–1600 bar; vacuum variants.
Units
bar, psi, kPa, MPa or kg/cm².
Outputs
4–20 mA or 0–10 V; smart variants by model.
Max. error guide
±0.25 / ±0.5 / ±1% span at adjustment temperature.
Wetted parts
Stainless steel; diaphragm and seals to suit the media.

Indicative industry selection data, not guaranteed ASTREON model ratings. Confirm the final range, accuracy and configuration against the selected manufacturer datasheet.

Discuss your requirement

Humidity, gas & dew point

TEJ / CATALOGUEHumidity instruments from the TEJ product catalogue

Humidity

04 / 08

Monitor air humidity and temperature using wall, duct or remote-probe arrangements. Select the filter and mounting for contamination, airflow and maintenance access. Accuracy must be assessed across the actual humidity and temperature conditions.

Relative humidity
0–100% RH
Outputs
Voltage / RS-485
View specifications
Relative humidity
0–100% RH.
Temperature guide
−40 to +80 °C, probe-dependent.
Accuracy example
±1.5% RH at 0–90% RH and 0 to +40 °C.
Outputs
Voltage or RS-485, selected by model.
Construction
Room / duct / remote probe; suitable filter.

Indicative industry selection data, not guaranteed ASTREON model ratings. Confirm the final range, accuracy and configuration against the selected manufacturer datasheet.

Discuss your requirement
TEJ / CATALOGUEGas detection instruments from the TEJ product catalogue

Gas detection

06 / 08

Specify the target gas first. Electrochemical, infrared and catalytic technologies serve different gases. Confirm units, cross-sensitivity, calibration and alarms. Any hazardous-area approval must match the exact instrument configuration and installation.

Oxygen example
0–25% vol O₂
Combustible guide
0–100% LEL
View specifications
Oxygen example
0–25% vol O₂; gas-specific sensor.
Combustible guide
0–100% LEL; calibrated for the named gas.
Toxic gases
ppm ranges selected for CO, H₂S and other gases.
Signal options
4–20 mA / HART; relays or fieldbus by model.
Selection checks
Gas, response, calibration and exact approvals.

Indicative industry selection data, not guaranteed ASTREON model ratings. Confirm the final range, accuracy and configuration against the selected manufacturer datasheet.

Discuss your requirement

Catalogue ranges, accuracy, approvals and operating conditions depend on the selected model and application. Detailed specifications are confirmed with your requirement.

Additional connectivity & automation application guidance

Wider measurement-family concepts and selection guidance, retained alongside the catalogue products.

Representative industrial connectivity product-family concept
MULTI-BRAND SELECTION

Industrial connectivity

Signal conditioning, isolation, gateways, loggers and control-system interfaces.

What to specify

Signal type, channel count, protocol, power, network, recording and integration needs.

Discuss this application ↗

Connect the measurement to the response.

Define the operating conditions, interfaces and acceptance criteria before selecting equipment or committing to system performance.

Field

Capture a reading using the selected sensor or instrument.

Condition

Isolate, convert and validate the signal.

Connect

Integrate the PLC, HMI, gateway or logger.

Respond & record

Route alarms and operator actions, preserve trends and maintain calibration status.

Integration options include 4–20 mA, RTD, RS-485, Ethernet, dry contacts, Modbus, BACnet and SNMP, subject to selected equipment and scope. Local monitoring, alarming and recording can be engineered to continue during an internet outage. Equipment-control actions require approved site logic and interlocks.

← Explore all Sensors & Instrumentation solutions

Discuss your instrument requirements.

Tell us about your process, site conditions and required outcome. We’ll help you define the next step.