Illustrative instrumentation and calibration workstation with pressure and temperature instruments

ASTREON Instrumentation

The right instruments.
For your process.

Industrial sensors, measurement instruments and the support to bring them into your operation.

Find the right instrument.

Explore the new ASTREON Sensbox alongside ten instrument families, with matching catalogue images, application descriptions and selection data. Explore each group, review the specifications and share your application with us.

Portable sensing & recording

ASTREON Sensbox open instrument case with logger, signal modules, DC UPS and battery-backup compartment
ASTREON SENSBOX / PORTABLE MEASUREMENT
NEW TO THE ASTREON PORTFOLIO

ASTREON Sensbox

Bring surface temperature, humidity, air temperature, duct air velocity and filter differential pressure into one portable acquisition and recording case. Sensbox is designed around field connection, a visible logger and a matched backup-power path.

Measurement channels
8 connected channels
Power configuration shown
Mains + proposed battery backup
View sensor & battery mapping

Eight measurement channels, with humidity and air temperature sharing one remote probe. Channel numbering follows the supplied demonstration.

Sensor-to-channel mapping
ChannelMeasurementSensor / signal path
CH 01Supply duct surface temperatureSurface-contact thermocoupleThermocouple mV → type-matched conversion + cold-junction compensation → °C
CH 02Return duct surface temperatureSurface-contact thermocoupleThermocouple mV → type-matched conversion + cold-junction compensation → °C
CH 03Chilled-water supply surface temperatureSurface-contact thermocoupleThermocouple mV → type-matched conversion + cold-junction compensation → °C
CH 04Chilled-water return surface temperatureSurface-contact thermocoupleThermocouple mV → type-matched conversion + cold-junction compensation → °C
CH 05Relative humidityShared remote humidity / air-temperature probeInternal transmitter → independent 4–20 mA humidity signal → %RH
CH 06Air temperatureSame remote probe as channel 05Internal transmitter → independent 4–20 mA temperature signal → °C
CH 07Duct air velocityCable-connected thermal airspeed probeInternal transmitter → 4–20 mA → m/s
CH 08Filter differential pressureDifferential-pressure transmitter with HIGH / LOW tubesHIGH upstream − LOW downstream → internal transmitter → 4–20 mA → Pa

Battery & backup power

Battery shown
Bioenno Power BLF-2410A
Proposed battery configuration
24 V, 10 Ah LiFePO₄ compact protected pack
Power path
Matched charger and DC UPS path
Configuration check
Final load and enclosure to be verified, as stated in the demonstration

The video identifies this battery as a proposed configuration. Final battery, charger, DC UPS compatibility and load must be confirmed for the selected build; a verified operating runtime is not specified.

Pressure & temperature

TEJ / CATALOGUEPressure instruments from the TEJ product catalogue

Pressure

03 / 08

Select compact transmitters, process instruments or local gauges for pumps, compressors and hydraulic systems. Match the measuring span, overload capacity, wetted materials and connection to the medium. Confirm the total error at operating temperature.

Range options
0–0.4 to 0–1600 bar
Outputs
4–20 mA / 0–10 V
View specifications
Range options
0–0.4 to 0–1600 bar; vacuum variants.
Units
bar, psi, kPa, MPa or kg/cm².
Outputs
4–20 mA or 0–10 V; smart variants by model.
Max. error guide
±0.25 / ±0.5 / ±1% span at adjustment temperature.
Wetted parts
Stainless steel; diaphragm and seals to suit the media.

Indicative industry selection data, not guaranteed ASTREON model ratings. Confirm the final range, accuracy and configuration against the selected manufacturer datasheet.

Discuss your requirement
TEJ / CATALOGUEDifferential pressure instruments from the TEJ product catalogue

Differential pressure

03 / 08

Compare pressure across filters, cleanrooms or process equipment. Air-DP transmitters use low measuring spans; process-DP instruments require suitable wetted materials and static-pressure ratings. Select the port arrangement, span and output for the installation.

Air-DP spans
0–250 to 0–2500 Pa
Connections
H/L ports or process manifold
View specifications
Air-DP spans
0–250 to 0–2500 Pa; selected ranges.
Air-DP accuracy
±0.25 / ±1 / ±2% FS, by configuration.
Outputs
4–20 mA / voltage; process models: HART.
Media
Air or compatible gases; process duty specified separately.
Connections
H/L hose barbs or process manifold connections.

Indicative industry selection data, not guaranteed ASTREON model ratings. Confirm the final range, accuracy and configuration against the selected manufacturer datasheet.

Discuss your requirement
TEJ / CATALOGUETemperature instruments from the TEJ product catalogue

Temperature

04 / 08

Choose connection-head, cable, hygienic or thermocouple assemblies for machinery and process lines. Match the element, immersion length and sheath to the service. Thermowells and transmitters are selected separately to suit installation and control requirements.

RTD range guide
−196 to +600 °C
TC range guide
K/N: −40 to +1200 °C
View specifications
RTD range guide
−196 to +600 °C across suitable assemblies.
TC range guide
K/N: −40 to +1200 °C; class 2 examples.
Elements
Pt100 / Pt1000; thermocouple type to suit duty.
Signal chain
2/3/4-wire RTD; TC mV; transmitter: 4–20 mA.
Construction
Stainless sheath, selected length and connection.

Indicative industry selection data, not guaranteed ASTREON model ratings. Confirm the final range, accuracy and configuration against the selected manufacturer datasheet.

Discuss your requirement

Flow, level & weighing

TEJ / CATALOGUEFlow instruments from the TEJ product catalogue

Select electromagnetic, thermal, turbine or ultrasonic measurement for the fluid. Define the working flow, pipe size and installation conditions. The conductivity limit and numerical examples below apply specifically to electromagnetic liquid measurement.

Magmeter sizes
DN 25–3000
Velocity guide
0.01–10 m/s
View specifications
Magmeter sizes
DN 25–3000, configuration-dependent.
Velocity guide
0.01–10 m/s; select diameter for working flow.
Error example
±0.5% of reading plus ±1 mm/s.
Liquid suitability
Conductivity ≥5 µS/cm; suitable liner/electrodes.
Outputs
4–20 mA, pulse or digital; selected by model.

Indicative industry selection data, not guaranteed ASTREON model ratings. Confirm the final range, accuracy and configuration against the selected manufacturer datasheet.

Discuss your requirement
TEJ / CATALOGUELevel instruments from the TEJ product catalogue

Level

05 / 08

Select continuous measurement or point detection for tanks, vessels and silos. Radar, hydrostatic, float and vibrating-fork instruments address different duties. Review vessel geometry, deposits, foam, vapour and mounting before selecting the process connection and materials.

Radar span guide
Up to 120 m
Principles
Radar / hydrostatic / point
View specifications
Principles
Radar / hydrostatic / float / vibronic / capacitive.
Radar span guide
Up to 120 m with a suitable radar configuration.
Radar error guide
±1 mm under specified reference conditions.
Outputs
4–20 mA / HART; point switches: relay options.
Process contact
316L / PTFE and other media-compatible options.

Indicative industry selection data, not guaranteed ASTREON model ratings. Confirm the final range, accuracy and configuration against the selected manufacturer datasheet.

Discuss your requirement
TEJ / CATALOGUELoad & weighing instruments from the TEJ product catalogue

Load & weighing

06 / 08

Choose bending-beam, single-point, S-type or compression cells for the structure and load path. Size each cell for dead load, working load and overload. Compatible mounting hardware and separate electronics complete the weighing system.

Capacity example
5 kg to 1 t per cell
Cell signal
Strain-gauge bridge · mV/V
View specifications
Capacity example
Bending-beam variants: 5 kg to 1 t per cell.
Cell signal
Strain-gauge bridge; mV/V output.
Wiring
4-wire or 6-wire; matched excitation required.
Electronics
Separate indicator/transmitter: 4–20 mA or digital.
Construction
Steel / stainless; sealing and mounts to suit duty.

Indicative industry selection data, not guaranteed ASTREON model ratings. Confirm the final range, accuracy and configuration against the selected manufacturer datasheet.

Discuss your requirement

Humidity, gas & dew point

TEJ / CATALOGUEHumidity instruments from the TEJ product catalogue

Humidity

04 / 08

Monitor air humidity and temperature using wall, duct or remote-probe arrangements. Select the filter and mounting for contamination, airflow and maintenance access. Accuracy must be assessed across the actual humidity and temperature conditions.

Relative humidity
0–100% RH
Outputs
Voltage / RS-485
View specifications
Relative humidity
0–100% RH.
Temperature guide
−40 to +80 °C, probe-dependent.
Accuracy example
±1.5% RH at 0–90% RH and 0 to +40 °C.
Outputs
Voltage or RS-485, selected by model.
Construction
Room / duct / remote probe; suitable filter.

Indicative industry selection data, not guaranteed ASTREON model ratings. Confirm the final range, accuracy and configuration against the selected manufacturer datasheet.

Discuss your requirement
TEJ / CATALOGUEGas detection instruments from the TEJ product catalogue

Gas detection

06 / 08

Specify the target gas first. Electrochemical, infrared and catalytic technologies serve different gases. Confirm units, cross-sensitivity, calibration and alarms. Any hazardous-area approval must match the exact instrument configuration and installation.

Oxygen example
0–25% vol O₂
Combustible guide
0–100% LEL
View specifications
Oxygen example
0–25% vol O₂; gas-specific sensor.
Combustible guide
0–100% LEL; calibrated for the named gas.
Toxic gases
ppm ranges selected for CO, H₂S and other gases.
Signal options
4–20 mA / HART; relays or fieldbus by model.
Selection checks
Gas, response, calibration and exact approvals.

Indicative industry selection data, not guaranteed ASTREON model ratings. Confirm the final range, accuracy and configuration against the selected manufacturer datasheet.

Discuss your requirement
TEJ / CATALOGUEDew point instruments from the TEJ product catalogue

Dew point

07 / 08

Monitor moisture in compressed air, dryers and suitable dry gases using compact probes, remote displays or sampling arrangements. Define pressure or atmospheric dew point explicitly. Match the sensor, pressure rating and sampling conditions to the required dryness.

Dew/frost point
Typically −70 to +60 °C
Pressure example
0–50 bar absolute
View specifications
Dew/frost point
Typical measuring range: −70 to +60 °C.
Accuracy guide
±2 °C within the specified accuracy envelope.
Pressure example
0–50 bar absolute for suitable probe variants.
Outputs
4–20 mA / voltage / RS-485, model-dependent.
Installation
Direct insertion or controlled sample chamber.

Indicative industry selection data, not guaranteed ASTREON model ratings. Confirm the final range, accuracy and configuration against the selected manufacturer datasheet.

Discuss your requirement

Calibration

TEJ / CATALOGUECalibrators instruments from the TEJ product catalogue

Calibrators

07 / 08

Our calibrator offering supports commissioning and maintenance. Multifunction units source electrical and temperature-sensor signals; dry blocks and pressure pumps provide physical references. The benchmarks below apply to separate equipment types, with final model selection required.

Dry-block range
−25 to +150 °C
Hydraulic pressure
0–1000 bar pump
View specifications
DC current
Source 0.100–22.000 mA; measure up to 110 mA.
Source accuracy
±(0.01% output + 3 µA); 1 year, 18–28 °C, 5 min warm-up.
Dry-block range
−25 to +150 °C at 23 °C ambient.
Dry-block guide
Display: ±0.2 °C; stability: ±0.01 °C.
Hydraulic pressure
0–1000 bar pump; matched reference required.

Indicative industry selection data, not guaranteed ASTREON model ratings. Confirm the final range, accuracy and configuration against the selected manufacturer datasheet.

Discuss your requirement

Technical tables are indicative industry selection guides, not guaranteed ASTREON model ratings. Confirm the final range, accuracy, availability and configuration against the selected manufacturer datasheet.

Open complete catalogue · PDF, 8 pages ↗
Explore the wider measurement portfolio · 13 families

Additional application-selection guidance. These representative product-family concepts include the catalogue families above and additional measurement applications.

Representative pressure product-family concept
MULTI-BRAND SELECTION

Pressure

Select compact transmitters, process instruments or local gauges for pumps, compressors and hydraulic systems. Match the measuring span, overload capacity, wetted materials and connection to the medium. Confirm the total error at operating temperature.

What to specify

Range, gauge or absolute reference, media, wetted materials, process connection and output.

Discuss this application ↗
Representative differential pressure product-family concept
MULTI-BRAND SELECTION

Differential pressure

Compare pressure across filters, cleanrooms or process equipment. Air-DP transmitters use low measuring spans; process-DP instruments require suitable wetted materials and static-pressure ratings. Select the port arrangement, span and output for the installation.

What to specify

Differential range, static pressure, media, manifold arrangement and mounting.

Discuss this application ↗
Representative temperature product-family concept
MULTI-BRAND SELECTION

Temperature

Choose connection-head, cable, hygienic or thermocouple assemblies for machinery and process lines. Match the element, immersion length and sheath to the service. Thermowells and transmitters are selected separately to suit installation and control requirements.

What to specify

Temperature range, sensing element, insertion length, sheath, connection and output.

Discuss this application ↗
Representative flow product-family concept
MULTI-BRAND SELECTION

Flow

Select electromagnetic, thermal, turbine or ultrasonic measurement for the fluid. Define the working flow, pipe size and installation conditions. The conductivity limit and numerical examples below apply specifically to electromagnetic liquid measurement.

What to specify

Fluid, line size, operating pressure, temperature, flow range and installation conditions.

Discuss this application ↗
Representative level product-family concept
MULTI-BRAND SELECTION

Level

Select continuous measurement or point detection for tanks, vessels and silos. Radar, hydrostatic, float and vibrating-fork instruments address different duties. Review vessel geometry, deposits, foam, vapour and mounting before selecting the process connection and materials.

What to specify

Material, vessel geometry, process conditions, mounting and switching requirements.

Discuss this application ↗
Representative load & weighing product-family concept
MULTI-BRAND SELECTION

Load & weighing

Choose bending-beam, single-point, S-type or compression cells for the structure and load path. Size each cell for dead load, working load and overload. Compatible mounting hardware and separate electronics complete the weighing system.

What to specify

Capacity, mounting, mechanical arrangement, overload, environment and indication.

Discuss this application ↗
Representative humidity product-family concept
MULTI-BRAND SELECTION

Humidity

Monitor air humidity and temperature using wall, duct or remote-probe arrangements. Select the filter and mounting for contamination, airflow and maintenance access. Accuracy must be assessed across the actual humidity and temperature conditions.

What to specify

Humidity and temperature range, environment, probe location and output.

Discuss this application ↗
Representative dew point product-family concept
MULTI-BRAND SELECTION

Dew point

Monitor moisture in compressed air, dryers and suitable dry gases using compact probes, remote displays or sampling arrangements. Define pressure or atmospheric dew point explicitly. Match the sensor, pressure rating and sampling conditions to the required dryness.

What to specify

Gas, dew-point range, operating pressure, sampling and connection.

Discuss this application ↗
Representative proximity & position product-family concept
MULTI-BRAND SELECTION

Proximity & position

Non-contact object and position detection for equipment and automation.

What to specify

Target material, sensing distance, mounting, switching output and environment.

Discuss this application ↗
Representative vibration product-family concept
MULTI-BRAND SELECTION

Vibration

Vibration sensing for machine-condition measurement and trending.

What to specify

Machine type, measurement axis, frequency range, mounting and acquisition interface.

Discuss this application ↗
Representative speed product-family concept
MULTI-BRAND SELECTION

Speed

Rotational speed sensing for machines and moving equipment.

What to specify

Speed range, target geometry, sensing gap, output and controller compatibility.

Discuss this application ↗
Representative gas detection product-family concept
MULTI-BRAND SELECTION

Gas detection

Specify the target gas first. Electrochemical, infrared and catalytic technologies serve different gases. Confirm units, cross-sensitivity, calibration and alarms. Any hazardous-area approval must match the exact instrument configuration and installation.

What to specify

Target gas, range, location, alarm interface and required approvals.

Discuss this application ↗
Representative industrial connectivity product-family concept
MULTI-BRAND SELECTION

Industrial connectivity

Signal conditioning, isolation, gateways, loggers and control-system interfaces.

What to specify

Signal type, channel count, protocol, power, network, recording and integration needs.

Discuss this application ↗

Support throughout the instrument lifecycle.

Selection, documentation review, mounting, wiring, configuration and commissioning all affect measurement quality. We help connect these steps and plan subsequent checks, recalibration and replacement.

Explore calibration & lifecycle support ↗

Discuss your measurement requirements.

Tell us about your process, site conditions and required outcome. We’ll help you define the next step.

Discuss your requirement ↗