Select for the process.

Pressure, differential pressure, temperature, flow and level instrumentation. Begin with the parameter, media, range and installation conditions.

Pressure instruments from the ASTREON sensor catalogue.
Pressure instruments from the ASTREON sensor catalogue.

The right instrument for the process.

Compare pressure, temperature, flow and level options from the catalogue. Confirm the selected model against your media, operating range, installation and signal requirements.

Pressure & temperature

TEJ / CATALOGUEPressure instruments from the TEJ product catalogue

Pressure

03 / 08

Select compact transmitters, process instruments or local gauges for pumps, compressors and hydraulic systems. Match the measuring span, overload capacity, wetted materials and connection to the medium. Confirm the total error at operating temperature.

Range options
0–0.4 to 0–1600 bar
Outputs
4–20 mA / 0–10 V
View specifications
Range options
0–0.4 to 0–1600 bar; vacuum variants.
Units
bar, psi, kPa, MPa or kg/cm².
Outputs
4–20 mA or 0–10 V; smart variants by model.
Max. error guide
±0.25 / ±0.5 / ±1% span at adjustment temperature.
Wetted parts
Stainless steel; diaphragm and seals to suit the media.

Indicative industry selection data, not guaranteed ASTREON model ratings. Confirm the final range, accuracy and configuration against the selected manufacturer datasheet.

Discuss your requirement
TEJ / CATALOGUEDifferential pressure instruments from the TEJ product catalogue

Differential pressure

03 / 08

Compare pressure across filters, cleanrooms or process equipment. Air-DP transmitters use low measuring spans; process-DP instruments require suitable wetted materials and static-pressure ratings. Select the port arrangement, span and output for the installation.

Air-DP spans
0–250 to 0–2500 Pa
Connections
H/L ports or process manifold
View specifications
Air-DP spans
0–250 to 0–2500 Pa; selected ranges.
Air-DP accuracy
±0.25 / ±1 / ±2% FS, by configuration.
Outputs
4–20 mA / voltage; process models: HART.
Media
Air or compatible gases; process duty specified separately.
Connections
H/L hose barbs or process manifold connections.

Indicative industry selection data, not guaranteed ASTREON model ratings. Confirm the final range, accuracy and configuration against the selected manufacturer datasheet.

Discuss your requirement
TEJ / CATALOGUETemperature instruments from the TEJ product catalogue

Temperature

04 / 08

Choose connection-head, cable, hygienic or thermocouple assemblies for machinery and process lines. Match the element, immersion length and sheath to the service. Thermowells and transmitters are selected separately to suit installation and control requirements.

RTD range guide
−196 to +600 °C
TC range guide
K/N: −40 to +1200 °C
View specifications
RTD range guide
−196 to +600 °C across suitable assemblies.
TC range guide
K/N: −40 to +1200 °C; class 2 examples.
Elements
Pt100 / Pt1000; thermocouple type to suit duty.
Signal chain
2/3/4-wire RTD; TC mV; transmitter: 4–20 mA.
Construction
Stainless sheath, selected length and connection.

Indicative industry selection data, not guaranteed ASTREON model ratings. Confirm the final range, accuracy and configuration against the selected manufacturer datasheet.

Discuss your requirement

Flow, level & weighing

TEJ / CATALOGUEFlow instruments from the TEJ product catalogue

Select electromagnetic, thermal, turbine or ultrasonic measurement for the fluid. Define the working flow, pipe size and installation conditions. The conductivity limit and numerical examples below apply specifically to electromagnetic liquid measurement.

Magmeter sizes
DN 25–3000
Velocity guide
0.01–10 m/s
View specifications
Magmeter sizes
DN 25–3000, configuration-dependent.
Velocity guide
0.01–10 m/s; select diameter for working flow.
Error example
±0.5% of reading plus ±1 mm/s.
Liquid suitability
Conductivity ≥5 µS/cm; suitable liner/electrodes.
Outputs
4–20 mA, pulse or digital; selected by model.

Indicative industry selection data, not guaranteed ASTREON model ratings. Confirm the final range, accuracy and configuration against the selected manufacturer datasheet.

Discuss your requirement
TEJ / CATALOGUELevel instruments from the TEJ product catalogue

Level

05 / 08

Select continuous measurement or point detection for tanks, vessels and silos. Radar, hydrostatic, float and vibrating-fork instruments address different duties. Review vessel geometry, deposits, foam, vapour and mounting before selecting the process connection and materials.

Radar span guide
Up to 120 m
Principles
Radar / hydrostatic / point
View specifications
Principles
Radar / hydrostatic / float / vibronic / capacitive.
Radar span guide
Up to 120 m with a suitable radar configuration.
Radar error guide
±1 mm under specified reference conditions.
Outputs
4–20 mA / HART; point switches: relay options.
Process contact
316L / PTFE and other media-compatible options.

Indicative industry selection data, not guaranteed ASTREON model ratings. Confirm the final range, accuracy and configuration against the selected manufacturer datasheet.

Discuss your requirement

Catalogue ranges, accuracy, approvals and operating conditions depend on the selected model and application. Detailed specifications are confirmed with your requirement.

Additional process measurement application guidance

Wider measurement-family concepts and selection guidance, retained alongside the catalogue products.

Representative pressure product-family concept
MULTI-BRAND SELECTION

Pressure

Select compact transmitters, process instruments or local gauges for pumps, compressors and hydraulic systems. Match the measuring span, overload capacity, wetted materials and connection to the medium. Confirm the total error at operating temperature.

What to specify

Range, gauge or absolute reference, media, wetted materials, process connection and output.

Discuss this application ↗
Representative differential pressure product-family concept
MULTI-BRAND SELECTION

Differential pressure

Compare pressure across filters, cleanrooms or process equipment. Air-DP transmitters use low measuring spans; process-DP instruments require suitable wetted materials and static-pressure ratings. Select the port arrangement, span and output for the installation.

What to specify

Differential range, static pressure, media, manifold arrangement and mounting.

Discuss this application ↗
Representative temperature product-family concept
MULTI-BRAND SELECTION

Temperature

Choose connection-head, cable, hygienic or thermocouple assemblies for machinery and process lines. Match the element, immersion length and sheath to the service. Thermowells and transmitters are selected separately to suit installation and control requirements.

What to specify

Temperature range, sensing element, insertion length, sheath, connection and output.

Discuss this application ↗
Representative flow product-family concept
MULTI-BRAND SELECTION

Flow

Select electromagnetic, thermal, turbine or ultrasonic measurement for the fluid. Define the working flow, pipe size and installation conditions. The conductivity limit and numerical examples below apply specifically to electromagnetic liquid measurement.

What to specify

Fluid, line size, operating pressure, temperature, flow range and installation conditions.

Discuss this application ↗
Representative level product-family concept
MULTI-BRAND SELECTION

Level

Select continuous measurement or point detection for tanks, vessels and silos. Radar, hydrostatic, float and vibrating-fork instruments address different duties. Review vessel geometry, deposits, foam, vapour and mounting before selecting the process connection and materials.

What to specify

Material, vessel geometry, process conditions, mounting and switching requirements.

Discuss this application ↗

Connect the measurement to the response.

Define the operating conditions, interfaces and acceptance criteria before selecting equipment or committing to system performance.

Field

Capture a reading using the selected sensor or instrument.

Condition

Isolate, convert and validate the signal.

Connect

Integrate the PLC, HMI, gateway or logger.

Respond & record

Route alarms and operator actions, preserve trends and maintain calibration status.

Integration options include 4–20 mA, RTD, RS-485, Ethernet, dry contacts, Modbus, BACnet and SNMP, subject to selected equipment and scope. Local monitoring, alarming and recording can be engineered to continue during an internet outage. Equipment-control actions require approved site logic and interlocks.

← Explore all Sensors & Instrumentation solutions

Discuss your instrument requirements.

Tell us about your process, site conditions and required outcome. We’ll help you define the next step.

Discuss your requirement ↗